StP Ltd

SComplex Burglar Alarm

SComplex Burglar Alarm System consists of a burglar alarm system centre and privacy protection enhancers connected to the centre by an SC485 line. It is applicable efficiently even in privacy protection systems with small (8-32), medium (32-256) and big (256-4096) amount of zones. In case of the biggest installation it can register the first alarm in 1 second.

In maximal installation

  • Number of inputs: 4096
  • Number of partitions: 4096
  • Number of outputs: 1536
  • Number of users: 64
  • Event memory: 200 000

SC-Alarm technical data

Burglar alarm control panel

  • Number of SC485/RS485 lines: 4
  • Maximum number of enhancer driver per lines: 16
  • Every input may be a separate partition
  • Line characteristics: supervised fire, doorbell, delayed, follower, silent, 24-hours, sabotage
  • Sabotage signals are stored in non-volatile memory until acknowledgement
  • All zones are named individually
  • Size of event memory: 200 000
  • Number of users: 10 000
  • Identification of users by proximity card or code
  • Authority of users may be freely set
  • Remote supervision signal: Contact ID
  • 72 hours of uninterrupted operation (needs accumulator enhancement)

Zone expander

  • 8/6 – 16/6 – 32/6 input/output
  • Termination types EOL / DEOL / NC / NO may be set by the software for every input
  • Terminating resistors of 1k / 2.2k / 4.7k / 5.1k / 5.6k may be set by the software for every input
  • Supply voltage monitoring
  • Supply voltage: 8V-16V
  • Current: 30 mA
  • May be connected to the bus SNET RS485 of the SC-Alarm

Alarm keypad

  • LCD interface of 2 x 16 characters with background light
  • 16 buttons
  • Length of PIN code may be set between 4 and 16 digits
  • Time for entering code may be set between 1 and 256 seconds
  • Three false codes in a row suspends the keypad
  • Possibility for duress PIN code
  • Supply voltage: 8V-16V
  • Current: 100mA
  • May be connected
  • May be connected to the bus SNET RS485 of the SC-Alarm